6 Types of Cooling Tower Fills from Manufacturer in India

15 Mar.,2024

 

    Cooling Tower PVC Fills

    While the reason for a cooling tower rotates around water, the genuine heart of any cooling tower is the fill. Fill, or wet deck or surface, is a medium utilized as a part of cooling towers to build the surface region of the tower. Expanded surface territory considers most extreme contact between the air and the water, which takes into consideration more prominent dissipation rates. The fill gives a tremendously extended air-water interface for warming of the air and vanishing to occur. The water is cooled as it slides through the fill by gravity while in immediate contact with air that disregards it. The cooled water is then gathered in a frosty water bowl beneath the fill from which it is pumped again through the procedure to assimilate more high temperature. The warmed and dampness laden air leaving the fill is released to the climate at a point remote enough from the air bays to keep its consistently stepped go into the cooling tower.


    The principle of operation of cooling tower fill is to put as much water surface area in contact with as much air as possible, for the longest amount of time possible. Film fills allow the water to form thin flowing sheets to expose as much water surface area as possible to the interacting flow.


    Cooling tower sheet fills or media, come in many different forms and “micro-structures,” each having unique characteristics to fit various applications. Film fills are selected for direct replacement, performance enhancement, and water condition compatibility. Each fill has performance characteristics that allow selections to be made for various heat loads, flow rates, water quality, and horse power combinations.


    Cooling tower fills of size 600 x 300 ( 1 CFT ) and 600 x 150 ( 1/2 CFT ) made of corrugated virging quality PVC film duly vacuum formed and edge folded for extended service life. Available in blue and black colors for cooling tower of FRP induced draft counter flow type and cross flow type. The edge folded technology will reduce the attrition loss of the fills and save the process equipment from fouling . extend the service life of pvc fills for years


    PVC Fills for Cooling Tower – We are one of the leading manufacturer & seller of PVC honey comb type corrugated PVC fills for cooling tower. Our fills are edge folded with 2. 35 mm thick virgin PVC film vacuum formed corrugated sheets pasted together to form the size of 600 x 300 x 150 mm having wetted surface area of 5. 85 sq. Mtr / CFT fill

    Drift Eliminators

    PERFECT offers Drift Eliminators, made out of rigid PVC, are designed to remove entrained particles from air steam efficiently, with minimum pressure drop, thereby reducing the fan power requirement when the air passes through the Drift Eliminator.


    Cooling tower fills of size 600 x 300 x 150 mm ( 1 CFT ) and 600 x 150 x 150 mm ( 1/2 CFT ) made of corrugated virging quality PVC film duly vacuum formed and edge folded for extended service life. Available in blue and black colors for cooling tower of FRP induced draft counter flow type and cross flow type. The edge folded technology will reduce the attrition loss of the fills and save the process equipment from fouling . extend the service life of pvc fills for years.

    Sigma Fills

    We are also one of the leading manufacturer and supplier of sigma type fills suitable for crossflow make cooling towers . the dimension are as per customer requirement , based on tower make and model no.we undertake site installation work and also supply new cooling tower as well.

With high quality products and considerate service, we will work together with you to enhance your business and improve the efficiency. Please don't hesitate to contact us to get more details of PVC Cooling Tower Fill.